Frequency Minimum: 26 MHz
Frequency Maximum: 40 GHz
ANSI C63.4 Normalized Site Attenuation: 30 MHz to 40 GHz
- Design and Fabricate RF-shielded Enclosure
- Installation of the Enclosure and Absorber
- One Single-leaf, Manually Operated,
RF-shielded Personnel Door
- Raised, Reflective Ground Plane
- Access Hatches in Raised Floor, Nominally
30 cm (12 in) x 30 cm (12 in)
- Waveguide Vents, Nominally 30 cm (12 in) x
30 cm (12 in)
- 50/60 Hz Power-line Filters for EUT,
Lights, Antenna Tower and Turntable
- Connector Panels, Nominally 15 cm (6 in) x 60 cm
(24 in) Clear Opening
- Pipe Penetration
- Fiber Optic ST-type Feed-through Kits for Antenna
Tower and Turntable
- RF-shielded Penetration for Airline to Antenna
Tower (Compressed Air is Responsibility of
Customer)
- Corner-mounted Light Fixtures with Floodlights
(Electrical Distribution not Included in All Markets)
- Shielding Effectiveness Test at 1 GHz with the Test
Methods of MIL-STD-285/IEEE-299
- FerroSorb™ Hybrid Absorber
- Light Reflective Finish on the Walls and Ceiling
- FerroSorb Hybrid Floor Absorber on Sixteen (16)
Movable Carts for Immunity Testing
- EHP™ Microwave Floor Absorber for an Area of
the Floor for sVSWR Testing
- ETS-Lindgren Electrically Powered Turntable
- ETS-Lindgren Dual Device Controller
- ETS-Lindgren Boresight Antenna Tower;
Electrically Powered and Air Polarization
- Warranty as per ETS-Lindgren’s Standard
Warranty for Anechoic Chambers
and Associated Equipment
Chamber Options
-
Fully Integrated Test System to Meet the Requirements Of A Particular Test Standard
-
Shielded Control Room
-
Shielded Amplifier Room
-
Model LDT-1.5 Low Dielectric Table
-
30 cm (12 in) and 45 cm (18 in) Raised Floors
-
Low Profile Door Sill
-
Sliding Door
-
CCTV Monitoring System
-
Intercom System
-
Fire Detection And Suppression System
-
Other Door Options Available
-
Anti-static Vinyl Floor Tile
-
Additional RF Filtering
-
Company Logo Screen Printed Onto White Caps
-
Immunity Interlock Switch
-
Electrical Distribution
-
Heating, Ventilation, And Air Conditioning (HVAC) System
-
Seismic Structural Design Calculations And Certification
Chamber Acceptance Testing Options
-
FU Test per IEC 61000-4-3 From 80 MHz to 1 GHz
-
FU Test per IEC 61000-4-3 From 1 GHz to 18 GHz
-
NSA Test (3 meter) per ANSI C63.4/CISPR 16-1-4 From 30 MHz to 1 GHz
-
NSA Test (5 meter) per ANSI C63.4/CISPR 16-1-4 From 30 MHz to 1 GHz
-
sVSWR Test per CISPR 16-1-4/ANSI C63.4 From 1 GHz to 18 GHz