Frequency Minimum: 26 MHz
Frequency Maximum: 18 GHz
Absorber Type: EHP-18CL Absorber; FS-1500; FT-100; FT-100c; FT-2000
IEC 1000-4-3 Field Uniformity: 0+6 dB; 1.5 m x 1.5 m (3.92 ft x 3.92 ft); 26 MHz to 18 GHz; 75% 16 Points
- FACT 10-3.0 Plus
Modular RF-shielded enclosure with nominal inside shield dimensions of 63’-6” x 37’-9 ½” x 27’-9 ½” (19.35m x 11.52m x 8.47m)
Note: Height measured above the ground plane raised floor
Estimated overall chamber dimensions of 65'-4" x 40'-0" x 31'-8" (19.91m x 12.19m x 9.65m)
- FACT 10-3.0 Premium
Modular RF-shielded enclosure with nominal inside shield dimensions of 63’-6” x 37’-9 ½” x 27’-9 ½” (19.35m x 11.52m x 8.47m)
Note: Height measured above the ground plane raised floor
Estimated overall chamber dimensions of 65'-4" x 40'-0" x 31'-8" (19.91m x 12.19m x 9.65m)
- FACT 10-4.0 Standard
- Modular RF-shielded enclosure with nominal inside shield dimensions of 65’-5” x 35’-11” x 21’-10” (19.94m x 10.95m x 6.65m)
- Estimated overall chamber dimensions of 67'-3" x 38'-1" x 25'-9" (20.50m x 11.61m x 7.85m)
- FACT 10-4.0 Plus
- Modular RF-shielded enclosure with nominal inside shield dimensions of 65’-5” x 39’-10” x 27’-10” (19.94m x 12.14m x 8.48m)
- Estimated overall chamber dimensions of 67'-3" x 42'-0" x 31'-9" (20.50m x 12.80m x 9.68m)
- FACT 10-6.0 Plus
- Modular RF-shielded enclosure with nominal inside shield dimensions of 71’-6” x 43’-6” x 27’-10” (21.79m x 13.26m x 8.48m
- Estimated overall chamber dimensions of 73'-4" x 45'-8" x 31'-9" (22.35m x 13.92m x 9.68m)
- 3 m Quiet Zone
- Design and fabricate RF-shielded enclosure, interior nominal shield-to-shield dimensions of 18.78 m L x 11.56 m W x 8.93 m H (61.6 ft x 37.8 ft x 29.3 ft) includes 45.72 cm (18 in) raised floor.
- 4 m Quiet Zone:
- Design and fabricate RF-shielded enclosure, interior nominal shield-to-shield dimensions of 19.42 m L x 12.17 m W x 8.93 m H (63.6 ft x 39.8 ft x 27.8 ft) includes 45.72 cm (18 in) raised floor.
- 6 m Quiet Zone:
- Design and fabricate RF-shielded enclosure, interior nominal shield-to-shield dimensions of 21.82 m L x 13.28 m W x 9.10 m H (71.5 ft x 43.5 ft x 29.8 ft) includes 60.96 (24 in) raised floor.
- Two Access Hatches in Raised Floor
- Dielectric Vapor Barrier and Masonite Underlayment
- Model 2175 MiniMast™ Electrically Powered Air Polarization Boom Tower with 20 m Cable and Fiber Optic Feed-through
- One RF-shielded Penetration for Airline to MiniMast (Compressed Air is Responsibility of Customer)
- Two Door Maintenance Kits
- One Threaded Brass Ground Stud 1.27 cm (0.5 in) Diameter x 12.7 cm (5 in) Long
- One Single-leaf, Series 201, Recessed Contact Mechanism (RCM), Manually Operated, RF-Shielded Personnel Door, .91 m x 2.13 m (3 ft x 7 ft) Clear Opening
- FT-1500 on the Doors
- Raised, Reflective Ground Plane, 45.72 cm (18 in)
- Model 2090 Dual Device Controller
- Four "N" Type Connectors
- Design and Fabricate RF-shielded Enclosure, Interior Nominal Shield-to-shield Dimensions of 18.81 m L x 11.56 m W x 6.97 m H, (61.71 ft x 37.93 ft x 22.87 ft) includes 45.72 cm (18 in) Raised Floor
- Four Single Line, 100 Amp, 60 Hz, Power-line Filters (Wiring not included)
- Two 2 x 30 Amp, 60 Hz Power-line Filters for Turntable (Wiring not included)
- FS-1500 Hybrid Absorber for all Four Walls up to the 9th Row
- Light Reflective Covers for the FS-1500, Hybrid Absorber on the Chamber Walls
- Sixteen Pieces of EHP-18PCL Pyramidal Absorber on an Area of the Floor for Radiated Immunity Testing from 1 GHz up to 40 GHz
- FT-100 from the 9th Row to Ceiling for all Four Walls
- Installation of the Enclosure and Absorber
- One RFSD-F-100 Automatic, Sliding RF-shielded Equipment Door
- 3.18 mm (.125 in) Vinyl Floor Tile
- Four Waveguide Vents, 60.96 cm x 30.48 cm (24 in x 12 in)
- Field Uniformity Calibration per IEC 61000-4-3 from 26 MHz to 1 GHz (Optional Test from 1 GHz to 18 GHz)
- Seismic Structural Design Calculations and Certification
- One Connector Panel, 30.48 cm x 60.96 cm (12 in x 24 in)
- One Fiber Optic Penetration Kit
- One Design Review at Customer's Location
- 2081-3.03 Electrically Powered, 3 m Turntable with Cable and Fiber Optic Feed-through
- Normalized Site Attenuation Test per ANSI C63.4 from 30 MHz to 1 GHz (Optional Test from 1 GHz to 18 GHz)
- One 3.81 cm (1.5 in) Pipe Penetration with Flange Nuts and Cap
- Shield Test per MIL-STD-285, One Frequency Test at 1 GHz
- Twelve High-hat Light Fixtures with Integral Waveguide Air Vents (Electrical Distribution not included)
- Guaranteed Performance and a Five-year Limited Warranty; One-year Warranty on Doors, Filters and Moving Parts; Two-year Warranty on Optional ETS-Lindgren Equipment
- Shielded control room, 4.87 m x 3.05 m x 2.44 m (16 ft x 10 ft x 8 ft)
- Compact-sized shielded control room, 3.66 m x 3.05 m x 2.44 m (12 ft x 10 ft x 8 ft)
- Shielded amplifier room, 2.44 m x 2.44 m x 2.44 m (8 ft x 8 ft x 8 ft)
- CCTV monitoring system
- Intercom system
- Fire detection and suppression system
- 3.18 mm (1/8”) anti-static vinyl floor tile
- Extra filtering
- Company logo screen printed onto white end caps
- Immunity interlock switch
- Electrical distribution
- Heating, ventilation, and air conditioning (HVAC) system
- Seismic structural design calculations and certification
- Normalized Site Attenuation measurement up to 18 GHz and 40 GHz
- Field uniformity measurement up to 18 GHz
- Assistance in preparation of FCC filing paperwork (Class B)